题名 | Arteriosclerosis Assessment Based on Single-Point Fingertip Pulse Monitoring Using a Wearable Iontronic Sensor |
作者 | |
通讯作者 | Zhao,Lingyu; Shi,Jidong; Guo,Chuan Fei |
发表日期 | 2023
|
DOI | |
发表期刊 | |
ISSN | 2192-2640
|
EISSN | 2192-2659
|
卷号 | 12 |
摘要 | Arteriosclerosis, which appears as a hardened and narrowed artery with plaque buildup, is the primary cause of various cardiovascular diseases such as stroke. Arteriosclerosis is often evaluated by clinically measuring the pulse wave velocity (PWV) using a two-point approach that requires bulky medical equipment and a skilled operator. Although wearable photoplethysmographic sensors for PWV monitoring are developed in recent years, likewise, this technique is often based on two-point measurement, and the signal can easily be interfered with by natural light. Herein, a single-point strategy is reported based on stable fingertip pulse monitoring using a flexible iontronic pressure sensor for heart-fingertip PWV (hfPWV) measurement. The iontronic sensor exhibits a high pressure-resolution on the order of 0.1 Pa over a wide linearity range, allowing the capture of characteristic peaks of fingertip pulse waves. The forward and reflected waves of the pulse are extracted and the time difference between the two waves is computed for hfPWV measurement using Hiroshi's method. Furthermore, a hfPWV-based model is established for arteriosclerosis evaluation with an accuracy comparable to that of existing clinical criteria, and the validity of the model is verified clinically. The work provides a reliable technique that can be used in wearable arteriosclerosis assessment systems. |
关键词 | |
相关链接 | [Scopus记录] |
收录类别 | |
语种 | 英语
|
学校署名 | 第一
; 通讯
|
WOS记录号 | WOS:001059117100001
|
EI入藏号 | 20233614664154
|
EI主题词 | Acoustic wave velocity
; Wave propagation
; Wearable sensors
|
EI分类号 | Acoustic Waves:751.1
; Pressure Measuring Instruments:944.3
|
Scopus记录号 | 2-s2.0-85169337055
|
来源库 | Scopus
|
引用统计 |
被引频次[WOS]:0
|
成果类型 | 期刊论文 |
条目标识符 | //www.snoollab.com/handle/2SGJ60CL/560090 |
专题 | 医院 工学院_材料科学与工程系 |
作者单位 | 1.Department of Cardiology,Southern University of Science and Technology Hospital (SUSTech-Hospital),Shenzhen,518071,China 2.Department of Materials Science and Engineering,Southern University of Science and Technology,Shenzhen,518055,China 3.CAS Key Laboratory of Mechanical Behavior and Design of Materials,Department of Modern Mechanics,University of Science and Technology of China,Hefei,230026,China 4.Shenzhen Key Laboratory of Biomimetic Robotics and Intelligent Systems,Guangdong Provincial Key Laboratory of Human-Augmentation and Rehabilitation Robotics in Universities,Southern University of Science and Technology,Shenzhen,518055,China 5.Department of Sports Center,Southern University of Science and Technology,Shenzhen,518055,China 6.Department of Endocrinology,Southern University of Science and Technology Hospital (SUSTech-hospital),Shenzhen,518071,China 7.Shenzhen Key Laboratory of Ultraintense Laser and Advanced Material Technology,Center for Advanced Material Diagnostic Technology,College of Engineering Physics,Shenzhen Technology University,Shenzhen,518118,China |
第一作者单位 | 医院 |
通讯作者单位 | 材料科学与工程系 |
第一作者的第一单位 | 医院 |
推荐引用方式 GB/T 7714 |
Huang,Yi,Zhao,Lingyu,Cai,Minkun,et al. Arteriosclerosis Assessment Based on Single-Point Fingertip Pulse Monitoring Using a Wearable Iontronic Sensor[J]. Advanced Healthcare Materials,2023,12.
|
APA |
Huang,Yi.,Zhao,Lingyu.,Cai,Minkun.,Zhu,Jiaqi.,Wang,Liu.,...&Guo,Chuan Fei.(2023).Arteriosclerosis Assessment Based on Single-Point Fingertip Pulse Monitoring Using a Wearable Iontronic Sensor.Advanced Healthcare Materials,12.
|
MLA |
Huang,Yi,et al."Arteriosclerosis Assessment Based on Single-Point Fingertip Pulse Monitoring Using a Wearable Iontronic Sensor".Advanced Healthcare Materials 12(2023).
|
条目包含的文件 | 条目无相关文件。 |
|